MF25 – 3.09 Installation, Operation & Maintenance Instructions 1200°C Vertical Chamber Furnaces VCF models This manual is for the gui
VCF 10 MF25 – 3.09 Example Element Connections The diagrams below give schematic examples only of how certain models may be connected, indicat
VCF 6.0 FAULT ANALYSIS A. Furnace Does Not Heat Up 1. The HEAT light is ON The heating element has failed Check also that the SSR i
VCF 12 MF25 – 3.09 7.0 CIRCUIT DIAGRAMS EMC Filters (if fitted): dependent on the model there may be one filter, or more than one fitted in pa
VCF 7.4 3-phase without neutral (delta – e.g. 208-240V) 7.5 3-phase without neutral (star – e.g. 380V and above)
VCF 14 MF25 – 3.09 8.0 FUSES & POWER SETTINGS 8.1 Fuses F1-F3: Refer to the circuit diagrams. F1 Internal supply fuses Fitted if suppl
VCF 9.0 SPECIFICATIONS Carbolite reserves the right to change specifications without notice. 9.1 Models Covered by this Manual MODEL Max.
VCF Carbolite, Parsons Lane, Hope, Hope Valley, S33 6RB, England. Telephone: +44 (0)1433 620011 Facsimile: +44 (0)1433 621198 E-mail: info@carbol
VCF 2 MF25 – 3.09 1.0 SYMBOLS & WARNINGS 1.1 Switches and Lights 1.2 Warning Symbols Instrument switch: when the instrumen
VCF 2.0 INSTALLATION 2.1 Unpacking & Handling When unpacking or moving the furnace always lift it by its base. Never lift it by the door
VCF 4 MF25 – 3.09 2.3 Electrical Connections Connection by a qualified electrician is recommended All furnaces covered by this manual may be
VCF 3.0 OPERATION The instructions for operating the temperature controller are given in a separate manual. If the furnace is fitted wit
VCF 6 MF25 – 3.09 3.3 Use of Probes Any metal object used to probe into the furnace chamber while the furnace is connected to the supply must b
VCF 4.0 MAINTENANCE 4.1 General Maintenance Preventive rather than reactive maintenance is to be preferred. The type and frequency depends on
VCF 8 MF25 – 3.09 5.0 REPAIRS & REPLACEMENTS 5.1 Safety Warning – Disconnection from Supply Always ensure that the furnace is disconnected
VCF Replace and reconnect the solid state relay ensuring that the heat-conducting thermal pad is sandwiched between the relay and the plate. A
Kommentare zu diesen Handbüchern